loading

We are a leading manufacturer of solar power utilization and lighting systems                   Mob:+86 199 2801 5868

The design of the light pole should be scientific and practical

Solar street lamps light pole battery components support of wind resistance design is according to the battery components manufacturer's technical parameters for the data. Solar energy battery components can bear the wind pressure of 2700 pa, if choose to 27 m/S wind resistance coefficient ( Typhoon is equivalent to 10) , according to the



solar street lamps light pole bracket of battery components of wind resistance design is according to the battery components manufacturer's technical parameters for the data. Solar energy battery components can bear the wind pressure of 2700 pa, if the wind resistance coefficient Decline in wind resistance coefficient is through the wind tunnel experiment and experiments to determine the parameters of a mathematical, use it to calculate the car on the road of air resistance. 】 Choose to 27 m/S ( Typhoon is equivalent to 10) , according to the viscous fluid mechanics [ The inviscid fluid mechanics is 2005 book, the author is Zeng Na dong. 】 Only 365 pa, battery components of wind pressure, the component itself to withstand 27 m/S wind speed without being damaged. Therefore, the design is the focus of the battery module bracket connected with lamp.

holder has two types: one is a built-in constant-current source 【 Constant current source, ac constant current source, dc constant current source, current generator, big current generator, also called a current source and stable current source, is a kind of wide spectrum, high precision ac current, has quick response speed, high precision of constant current, the long-term stability can work, suitable for all kinds of the nature of the load, Impedance, sensibility, capacitive) Wait for an advantage. 】 , and the other is without constant current source, without a constant current source of lamp holder is divided into three or more strings. If is persistence current source lamp holder, lamp holder on the output is connected directly to the battery negative output, when the lamp holder, separating from the controller, can check whether the lamp holder is normal light. A built-in constant-current source if you can't light, can be removed, change new constant-current source, or directly using the corresponding control constant current all-in-one. A built-in constant-current source if it can be open, the original is out of order, otherwise the lamp bead is broken. Likewise, if there is no lamp holder of constant current source, is replacing other good controller of the same project. If change after good, the original light pole controller has a problem, or there is something wrong with the lamp light source. Please check whether the lamp holder line has a problem, whether the lamp bead damage.

light pole should be paid attention to when installing the battery: the battery is the cathode must identify, it is strictly prohibited to reverse connection; Before installation should make corrosion processing for the terminal, the join welding or screws must be tightened according to regulations; For thermal insulation around the battery compartment should be to ensure that the battery good winter temperature; Underground storage battery library should be sealed to prevent water, ventilation pipe ( Outlet pipe) Should be unobstructed, keep the battery compartment ventilation and dry. Summer, if soaked in water, be sure to open the check, cleaning wiring devices, batteries are regularly check whether there is a semi-annual corrosion phenomena. Conditional word, can undertake battery maintenance, access door is opened, it is forbidden to access door smoking or ignition, because battery emits a small amount of hydrogen, using fire danger.

GET IN TOUCH WITH Us
recommended articles
Knowledge News & events Project
ALLTOP Cordially Invites You | Join Us at WETEX 2026 Dubai Solar PV Exhibition to Explore New Opportunities in the Middle East PV & Energy Storage Market!


Exhibition Name: WETEX 2026
Exhibition Dates: October 20–22, 2026
Venue: Dubai World Trade Centre · Dubai, UAE
ALLTOP Booth: 4C14
Warm Invitation | ALLTOP Debuts at the 140th Canton Fair, Jointly Witnessing a New Future of Green Energy

Exhibition Name: The 140th Canton Fair)
Exhibition Dates: October 15–19, 2026
Venue: China Import and Export Fair Complex, Guangzhou, China
ALLTOP Booth: Zone C · Hall 16.4 · Booths C34-C35, D08-D09
Golden Topping-Out Marks a New Milestone, Output Value Exceeds RMB 600 Million! ALLTOP Industrial Park’s 168,800 m² Project Successfully Topped Out

318 Days—Less Than a Year!

At the “Speed of Light,” from Blueprint to Topping-Out.

50.24 mu of Prime Land, 168,366 Square Meters of Intelligent Manufacturing Space,

Annual Output Value at Full Production Exceeding RMB 600 Million.

ALLTOP Speed, Formidable Strength, and a Promising Future!

Golden Topping-Out Shines, Output Value Soars
The Hype Is On! ALLTOP Draws Global Spotlight at the Solar Expo — Join Us for a Chat
SOLAR PV & ENERGY STORAGE WORLD EXPO 2026

Booth No.: 10.2· B551
Time: September 16–18
Address: China Import and Export Fair Complex, Guangzhou, China (No. 382 Yuejiang Middle Road, Haizhu District, Guangzhou)
ALLTOP UGANDA Invites You to Power and Elec Expo 2026

Exhibition Name: Power and Elec Expo 2026

Date: July 9th-11th 2026

Company Name: Alltop Engineering Uganda

Hall No.

Booth No. A45

Venue: UMA Show grounds, Multi-Purpose Hall, Kampala-Uganda
Our aim is to provide the best products and the most considerate service for customers.
About Us
Customer service