solar lamp benefit around now, but there are still many problems associated with, such as the dawn after installed, this may be in addition to accessories problem when assembling some link has a problem, although the installation is relatively simple, but in terms of assembly also needs certain technology.
as much as possible in order to avoid malfunction, solar lamp should be ready before installation debugging, and choose a sunny day, if installed in rainy day, just after the lights electricity is not charging, the battery is bad, it will not meet the design requirements. Note installed don't light on that day, after the installation connected controller, but don't pick up the load, the second day Bai Tianchong after one day, the evening to pick up the load, thus the capacity of the battery can achieve a higher degree. Of course, part of doing so would increase labor cost. Panels on the perspective of general factory is designed according to the degree of Angle, this is to ensure that the winter can have a good charge. But direction Angle is determined by the installation time, underground assembly of solar panels, found after the set up light pole Angle deviation, if partial, generally will not adjust. Solar panels of the angular deviation in addition to affect the charging, also affect the voltage of solar panels under the same light, can lead to solar energy lamp lights time error is larger. Therefore, when assembled on the ground, try to adjust the Angle of solar panels. Don't keep out as far as possible when installing solar panels, in order to achieve the lighting effects.
after installation failure occurs when the solar street lamps, generally divided into the following several ways:
. There is voltage on solar panels, but not charging, LEDI green light don't check the solar panels end interface controller contact and reliable.
。 Charge indicator LEDI ( Green light) Fast scintillation overpressure system voltage, check whether the battery is open circuit, or whether the battery connection is reliable. Or damage of charging circuit.
。 Load indicator LED A red light) Bright, but don't work load check whether the load end connection is reliable.
。 Load indicator LED A red light) Don't work fast scintillation, and load load short circuit.
。 Load indicator LED A red light) Slow flash, and does not load work load power is too large.
。 Red LED display, and don't work load battery voltage protection, charging, please.
。 Lamp holder. Of the cause of the fault, the line contact undesirable, electric, battery capacity serious decline, in the case of line no problem, replace the battery.
of course, solar lamp failure is not some artificial factors or caused by environmental factors, the main reason is the design of the solar street light itself, materials, etc. , so the quality is king.