High lamp manufacturers generally in 12 meters high above the light pole will be designed as two pole to splice, one reason is that the rod body is too long to transport, another reason is that high lamp light pole overall length is too long, it needs very large bending machine, if
high lamp' Light, generally refers to more than 15 meters steel conical light pole and high-power modular fixtures are composed of new type of lighting. 】 Manufacturers generally in 12 meters high above the light pole will be designed as two pole to splice, one reason is that the rod body is too long to transport, another reason is that high lamp light pole overall length is too long, it needs large bending machine, if such operation, high production cost of Shanghai solar energy light pole lamp will be high, in addition to this, the easier the longer the light of the lamp body deformation.
but plug will be influenced by many factors, such as light, are generally composed of two or four plug, in the process of splicing, if the splice improper operation, or incorrect splice direction will not straight after the installation of light, as a whole, especially standing in the light, the bottom look up and feel verticality can not meet the requirements, this often encounter the situation how should we do? Below we from the following points for processing.
1, first of all, let's look at the bottom section, there is a flange section, see if it is, measure it is one of the most simple way is vertical.
the operation method is to use a thin nylon rope tied to a heavy object, from the light, the position of about 10 meters, with the hand holding the top of the nylon rope, gravity natural prolapse, and then the nylon cord from the position of the eyes of 20 cm, with one eye by vertical line nylon rope and the bottom section of the light up wearing it.
if using this method in the north and south, east and west four directions wear after all no problem, the bottom section of the vertical degree even if they could.
if the bottom section of the found light, wear and nylon rope of the tree line there are serious not parallel, that this kind of situation will need to adjust, otherwise it will also not vertical section of the plug, and even the higher, the inclined, 'liang liang slanting' is.
2, check the plug part is in place, the general high lamp, communications tower, and beautify the tower, which require the splicing steel rod, when the design will have a theoretical depth of the plug.
if the actual depth of splice and theory of inserting depth differs a lot, more than 20 centimeters of above, the mount is likely to be not straight, only deep enough, can effectively guarantee the vertical effect.
3, if sure has been relatively vertical bottom section, other segments also have received a, if still not straight, this is only one possibility, that is inserting the wrong direction.
due to the light, most are designed to anise rod, high lamp manufacturer before the finished high lamp factory will make a series of splice test.