loading

We are a leading manufacturer of solar power utilization and lighting systems

Off-grid power generation system of solar energy storage outdoor lamp pool installation points

Acceptance of 1) Battery shall promptly carry out inspection after the arrival of the goods, because of the appearance defect tend to influence the internal quality of the products. 2) According to the battery factory time, determine whether need to supplement the electricity, and for a terminal voltage test and capacity, internal resistance testing. If

to accept 1) Battery after the arrival of the goods, should be timely check appearance defects often affect the internal quality of products. 2) According to the battery factory time to determine whether need to supplement the power supply, and the examination of the terminal voltage, capacity and internal resistance testing. If the battery only after the arrival of the goods for inspection, according to the time of delivery of the battery in the case of does not charge storage, cold storage time will be more than 6 months ( Temperature > 33 ℃ for 3 months) , its technical performance indicators will surely fall further, can't even use. ? Device battery installation quality directly affects the reliability of the operation, so the installation personnel must be trained or training to complete the battery installed. When handling the battery, not to mention pole, in order to avoid damage to the battery. Battery of seal leakage will cause the battery connector corrosion, directly affects the service life of batteries. Before installing the battery connector between the battery must be neatly arranged, shall be used for lubricant, or other chemicals, in order to avoid corrosion battery shell, shell burst and electrolyte leakage. Install battery technology conditions as follows: 1) Battery before installation, check the battery case, make sure that no physical damage. One end of the multimeter can be connected to the battery terminal, the other end can be connected to the appearance of wet wet suspects. If the voltage is zero volts, the shell will not damage. If the voltage is greater than zero volts, suggests that have acid. Need to be further examined. 2) Battery should be installed in a clean, cool, ventilated and dry place, and avoid direct sunlight. Stay away from the heater heat source or other radiation. Specific installation, should choose according to battery plate structure installation, shall not be tilted. Battery between ventilation measures should be taken to avoid the battery of combustible gas explode and burn. Because the battery in the process of charging and discharging will be fever, in order to ensure the battery good heat dissipation, the distance between the battery and battery generally greater than 50 mm. At the same time, the connection between the battery should meet the requirements of discharge current. For parallel connection, the battery impedance should be equal, battery, charging device and the connection between the load should not be used too thin or too long cable, so as to avoid in the process of current conduction the excessive voltage drop due to electricity and heat, and for the safe operation. 3) Before installing the battery, battery time interval between the production and installation. Battery open circuit voltage is measured, generally put into use in three months. If the battery to keep for a long time, the open circuit voltage is very low. At this point, the battery cannot be directly put into use. It should be in charge before use. After installation, should measure the battery voltage and DC gear digital instrument is used to measure the battery voltage. V is always greater than or equal to an integer. 12 ( V) ( N: relative to the number of battery 12 v battery series) ; If v is always less than Ntimes12 ( V) One by one, check the battery; If the two groups after battery series parallel, should in the connection of the two groups were measured before the storage battery voltage, the total v 1 is greater than or equal to Ntimes12 ( 5) ; V is a total of 2 is greater than or equal to the integer; 12 ( V) ( N: the number of battery series parallel branch) , two groups of battery terminal voltage error should be within the scope of the permit. 4) Battery could not use the old and new combination. Instead, should use the same set of all the new battery or all the old battery, in order to avoid imbalance, the status of the old and new batteries affect all battery service life and efficiency. For different capacity of the battery, and may not be in the same group in series. Otherwise, in the large current discharge or charge there are hidden dangers.

GET IN TOUCH WITH Us
recommended articles
Knowledge News & events Project
Leading the future of green energy storage, ALLTOP will appear at the 137th Canton Fair

Exhibition name: 2025 THE 137TH CHINA IMPORT AND EXPORT FAIRExhibition date: April 15-19, 2025Booth No. : 14.3 f33-34g10-11/14.2 D13-14-15Address: China Import and Export Fair Hall (Canton Fair Hall)
Somali municipal project: ALLTOP solar street lights light a green future
Project name: A municipal project (solar street lamp) in Somalia was successfully implemented
Date: January 04, 2025
Project location: Somalia
Quantity and specific configuration: 500 sets of 0278-400W solar street lights
ALLTOP presents innovative products at the 2024 Solar PV and Energy Storage World Expo
2024 Solar PV & Energy Storage World Expo The 16th Guangzhou Intt Solar Photovoltaic & Energy Storage Exhibition Booth No.Booth B551, Hall 10.2, Area B TIME/August 8th-10th, 2024 ADD: Area B, China Import & Export Fair Complex, Guangzhou
Pv + Agriculture: ALLTOP lights up Pakistani farms with green light, photovoltaic agricultural irrigation project is successful
While actively responding to the "Belt and Road" Initiative, ALLTOP should dig deep into overseas markets and carry out accurate market positioning and strategic planning. Comply with the current economic trend in the international situation, while ensuring that its products and services can meet the actual needs of countries along the "Belt and Road", and make ALLTOP unique products can achieve the purpose of truly serving the "Belt and Road", so as to achieve a soft landing and grounding; A pr
Shaping the Future of Energy ALLTOP at the Expo Georgia Exhibition Center
Live up to the old expectations! On April 26,The 28th International Exhibition for Buildi had its grand opening. ALLTOP team appeared in 118A, Hall 11.36, brought many new photovoltaic products, outdoor street lights, photovoltaic energy storage and other one-stop systematic solutions, attracted more than 300 industry leading enterprises to participate in the exhibition, many visitors have stopped to visit, exchange, tens of thousands of visitors, customers together, a glimpse of the annual indu
no data
Our aim is to provide the best products and the most considerate service for customers.
About Us
Customer service
detect