loading

We are a leading manufacturer of solar power utilization and lighting systems                   Mob:+86 199 2801 5868

Led street lamp manufacturers have noticed that the relevant national light pole

By quality supervision, inspection and quarantine of the People's Republic of China and China national standardization management committee GB7000 released on December 31, 2013. 203 - 2013 'lamps and lanterns - 2 Part 3: special requirements road and street lighting lamps and lanterns 'has been in July 1, 2015 formally implemented,

the state administration of quality supervision, inspection and quarantine of the People's Republic of China and China national standardization management committee GB7000 released on December 31, 2013. 203 - 2013 'lamps and lanterns - 2 Part 3: the special requirements for road and street lamp 'has been implemented on July 1, 2015. As a led lighting manufacturers, including solar lamp manufacturers, it is necessary to carefully study and research the difference between new and old national standard. Take timely measures to change does not conform to the stipulations of the new design, in the new product development and promotion management strictly enforce new rules and new standards, and to make some changes to your old standards. As a street lamp manufacturers, should pay special attention to the following: the installation height of different lamps and lanterns has different quality requirements, need to indicate in the product specification, with particular emphasis on the glass, the glass should be a) Made of glass, when lamps and lanterns is installed more than 5 m, the glass can be broken into small pieces; Or b) Made from glass with high impact strength; Or c) Glass cover of the new standard of security testing also by protecting methods ( Net cover and glass membrane layer, for example) Can modify the protection method in the glass fragments damage to stop it. In the old standards, on the basis of existing flat glass test methods, increase the molding of glass test method, and increases the optional conformity assessment method. This method requires the glass cover and satisfy the following two conditions: ( 1) With the pendulum or vertical drop after applying 5 joule impact energy, no broken glass. ( 2) Using the impact head breaking the glass. Of 50 mm in length square area in the number of shards of glass should be more than 20. Conformity assessment method of the old standard is to use impact head, after breaking the glass of 50 mm in length square area within the number of shards of glass should be more than 60. However, the new standard only requires the number of shards of glass more than 40. New regulations also limit the use of glass lid, asking customers under the temperature limit of glass manufacturers claim that the use of glass cover. Thermal limit should include a glass of minimum and maximum temperature and maximum allowable delta t value. I also want to remind all the led street lamp manufacturers, new wireless traffic lights since the implementation of laws and regulations related standards, regulations and certification will be changed. Because the manufacturer must be on the basis of the related technical data to modify internal standard and pay attention to the related department policy change at any time. Attachment: GB7000. 203 - 'Lamps and lanterns is 2-2013 Part 3: roads and street lighting lamps and lanterns 'learning website http://gb123 has special requirements. sac. gov. cn/gb/showGb? GBcode = 7000 GB。 203 - 2013

GET IN TOUCH WITH Us
recommended articles
Knowledge News & events Project
ALLTOP Cordially Invites You | Join Us at WETEX 2026 Dubai Solar PV Exhibition to Explore New Opportunities in the Middle East PV & Energy Storage Market!


Exhibition Name: WETEX 2026
Exhibition Dates: October 20–22, 2026
Venue: Dubai World Trade Centre · Dubai, UAE
ALLTOP Booth: 4C14
Warm Invitation | ALLTOP Debuts at the 140th Canton Fair, Jointly Witnessing a New Future of Green Energy

Exhibition Name: The 140th Canton Fair)
Exhibition Dates: October 15–19, 2026
Venue: China Import and Export Fair Complex, Guangzhou, China
ALLTOP Booth: Zone C · Hall 16.4 · Booths C34-C35, D08-D09
Golden Topping-Out Marks a New Milestone, Output Value Exceeds RMB 600 Million! ALLTOP Industrial Park’s 168,800 m² Project Successfully Topped Out

318 Days—Less Than a Year!

At the “Speed of Light,” from Blueprint to Topping-Out.

50.24 mu of Prime Land, 168,366 Square Meters of Intelligent Manufacturing Space,

Annual Output Value at Full Production Exceeding RMB 600 Million.

ALLTOP Speed, Formidable Strength, and a Promising Future!

Golden Topping-Out Shines, Output Value Soars
The Hype Is On! ALLTOP Draws Global Spotlight at the Solar Expo — Join Us for a Chat
SOLAR PV & ENERGY STORAGE WORLD EXPO 2026

Booth No.: 10.2· B551
Time: September 16–18
Address: China Import and Export Fair Complex, Guangzhou, China (No. 382 Yuejiang Middle Road, Haizhu District, Guangzhou)
ALLTOP UGANDA Invites You to Power and Elec Expo 2026

Exhibition Name: Power and Elec Expo 2026

Date: July 9th-11th 2026

Company Name: Alltop Engineering Uganda

Hall No.

Booth No. A45

Venue: UMA Show grounds, Multi-Purpose Hall, Kampala-Uganda
Our aim is to provide the best products and the most considerate service for customers.
About Us
Customer service