An overview, because 25 meters high lamp in the bad environment, long-term weathered, snow and rain erosion. Required by professional and technical personnel to carry out maintenance and conversion components, in order to enhance its service life, ensure the safety of the application. In order to ensure the maintenance work smoothly, formulate the
a overview,
for 25 meters high lamp conditions, long-term weathered, snow and rain erosion. Required by professional and technical personnel to carry out maintenance and conversion components, in order to enhance its service life, ensure the safety of the application. In order to ensure the maintenance work smoothly, to make the following safety technical countermeasures.
2, 25 meters high light pole maintenance preparation
1 and understand the engineering drawings of the 25 m light pole, make clear a regulation, in advance to prepare raw materials and special tools.
2, inspection equipment parts if everything is normal intact. Components such as: join anchor bolt fusion is solid, the rolling bearing is there RunHua, damaged parts should be immediately moved around.
3, check the earthing protection of the motor is strong, serious to rust antirust processing solution.
4, check the worm gear and worm reducer 【 Worm gear and worm reducer is a kind of dynamic convey institutions, using gear speed converter, motor ( The motor) Number of rotary rotary deceleration to want, and get a larger torque. 】 The safe coupling, Safety coupling ( Also called a torque limiter, torque limiter, safety clutch) , is one of the connection machine actively and work pattern in parts, the main function of overload protection, torque limiter is when required due to mechanical failure or overload torque than the set value, it is in the form of sliding limit the transmission of torque by the transmission system, after the overload situation disappear on its own recovery. 】 And the clutch. Remove the oil, add oil. Check the damage condition of gear and rack, when the drive gear thinning or have the trench should be moved around. Safe coupling not loose or adjust freely.
5, careful mother of galvanized steel wire rope lock lock should not have defects such as broken head, loose tube, galvanized steel wire rope of itself should not have bias, scattered, broken wires, indifference, dent, significant wear and corrosion condition, it is important to pay special attention to the rope and steel wire rope clip. In order to avoid corrosion of galvanized steel wire rope, and reduce the galvanized steel wire rope and galvanized steel wire rope and the cable drum, block between mutual damage, can make antirust processing plant oils with a stiff brush besmear is on galvanized steel wire rope.
6, check the limit switch' Limit switch is also called the trip switch, can be installed in a relatively static objects, Such as fixed frame, door frame, or still life, Or movement of objects, Such as driving, door, or animal) On. 】