Is said high lamp is complex, because it involves the elevator link in light plate, light plate rises if the imbalance will lead to the failure hook, rise too high and there will be a certain risk, if you want to install in place and well, just make sure you do a good job in the following two points. A,
say high lamp' Light, generally refers to more than 15 meters steel conical light pole and high-power modular fixtures are composed of new type of lighting. 】 Complex because it involves the elevator link in light plate, light plate rises if the imbalance will lead to the failure hook, rise too high and there will be a certain risk, if you want to install in place and well, just make sure you do a good job in the following two points.
a debugging, lamp plate: observe some square or light on either side of the road is not hard to find, a lot of ring and the lamp panel hook the gaps between the light pole is not symmetrical, far look lamp plate is inclined, is this why? Don't light pole is straightening? Many people are confused, in fact is not, I can very sure tell you, that is because not all the lamp panel hook hang up, just hung up the one or two, there are many factors that can lead to this situation, one of the most is the lamp plate with three elevator wire rope of debugging is not very uniform have high low, rises lamp plate must be inclined, sideways tied up lamp plate in touch, the first to touch the hook that is sure to hang up the street lamp factory, but because it is inclined, the hanging above didn't touch the hook up here, to rise again, this can hang the above already decoupling, so no matter how the whole always have one or two hooks for hanging.
2, limit problem: high lamp lifting system is bringing travel switch, the purpose is to rise to a certain position can be stopped automatically, this function can avoid light dish rise too high to result in wire rope pulley platform pulled off.
but light pole manufacturer tend not to include the travel switch, not because of fear of trouble, but after installing the switch can cause a lot of trouble, for example, there is something wrong with the switch, causing lamp tray also couldn't get on next Monday, finally still have to crane to solve, this kind of case. Without travel switch, also have certain risk, such as the night when installation, light pole hook is invisible, just touch the blind to rise is very dangerous, the bad will fall down. Not install the switch, and there is no danger way was also has, it is marked on the hoist rope, beside do another calibration, when the lamp panel into the scope of peg, the following tag on the steel wire rope in conformity with the scale, this time don't up, switch to the drop model, smooth lamp panel, in the it is both convenient and safe.
light, although the complex, but as long as can effectively meet the above two points, then all problems can be solved. If you really don't understand, it is recommended that the consultation specialized high lamp factory, lest cause safety accidents.